Approach direction
Horizontal
Guard locking type
| CEM?M2 | Guard locking actuated by energy ON and released by energy OFF. |
Combinations
| Guard locking solenoid | Safety switch | Actuator | Use |
|---|---|---|---|
| CES-C04 | for CES-C04 | ||
| CES-C07 | for CES-C07 |
| Material | |
| Solenoid | Steel, nickel-plated |
| Housing material | Aluminum |
| Weight | |
| Net | 0,45 kg |
| Ambient temperature | -25 … 50 °C |
| Degree of protection | IP 65, IP 67 |
| Mechanical life | |
| In case of use as door stop, and 1 Joule impact energy | 1 x 106 |
| Installation orientation | Any |
| Connection | M12, 5-pin |
| Guard locking principle | Open-circuit current principle |
| Locking force F | |
| (Not monitored, in axial direction) at UCM?24V | 650 N |
| Adhesive force | |
| by permanent magnet | 30 N 0+15 |
Electrical connection ratings
| Operating voltage DC | |
| UCM | 24 V DC -15% … +10% |
| Current consumption | 100 mA |
| Power consumption | 2,4 W |
| Solenoid duty cycle | 100 % |
Work area
| Assured switch-off distance Sar | |
| Assured switch-off distance Sar | max.17 mm |
| max.40 mm | |
| Assured operating distance Sao | |
| With center offset m=0 | min.5 mm |
| min.2 mm | |
| Center offset | |
| Solenoid | -2,5 … +2,5 mm |
| Transponder detection (typical value at room temperature) | -10 … +10 mm |