Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
Guard locking type
| STM2 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
Switching element
| UK | For monitoring the guard locking (built-in solenoid) slow-action switching contact 1 NC |
| SK | For monitoring the door/actuator position |
Combination available:
| 222 | Slow-action switching contact 2 NC |
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
| Housing material | Reinforced thermoplastic |
| Weight | |
| Net | 0,4 kg |
| Ambient temperature | -20 … 55 °C |
| Degree of protection | IP67 |
| Mechanical life | 2 x 106 |
| Contact material | Silver alloy, gold flashed |
| Switching principle | Slow-action switching contact |
| Installation orientation | Any |
| Number of door position positively driven contacts | 2 |
| Number of guard lock monitoring positively driven contacts | 1 |
| Connection | |
| 1 x | M20 x 1.5 |
| Approach speed | max.20 m/min |
| Actuation frequency | 1200 1/h |
| Guard locking principle | Open-circuit current principle |
| Locking force Fmax | 1000 N |
| Locking force FZh | 700 N |
| Retention force | 20 N |
| Extraction force | 30 N |
| Actuating force | 35 N |
| Insertion depth | min.24,5 mm |
Electrical connection ratings
| Thermal rated current Ith | 4 A |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 4A 230V |
| DC-13 | 4A 24V |
| Solenoid operating voltage | |
| AC/DC | 24 V -15% … +10% |
| Short circuit protection according to IEC 60269-1 | |
| (Fuse) | 4A gG |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 2,5 kV |
| Switching voltage | |
| Min. at 10mA | 12 V |
| Switching current | |
| Min. at 24V | 1 mA |
| Power consumption | 6 W |
| Solenoid duty cycle | 100 % |
| Connection cross-section | 0,34 … 1,5 mm? |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position | |
| B10D | 2 x 106 |
| Control of the guard locking | |
| Category | Depending on external control of guard locking |
| Performance Level | Depending on external control of guard locking |
| PFHD | Depending on external control of guard locking |
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
| Overtravel | 5 mm |