Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Increased overtravel for horizontal approach direction
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
Guard locking type
| TP1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
Switching element
| 4131 | Slow-action switching contact 2 NC + 2 NO |
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
| Housing material | Reinforced thermoplastic |
| Weight | |
| Net | 0,5 kg |
| Ambient temperature | -20 … 55 °C |
| Degree of protection | IP65 |
| Mechanical life | 1 x 106 |
| Contact material | Silver alloy, gold flashed |
| Switching principle | Slow-action switching contact |
| Installation orientation | Any |
| Number of door position positively driven contacts | 2 |
| Number of NO contacts | 2 |
| Connection | |
| 1 x | Plug connector SR11 |
| Approach speed | |
| max. | 20 m/min |
| Actuation frequency | 1200 1/h |
| Guard locking principle | Closed-circuit current principle |
| Locking force Fmax | 1300 N |
| Locking force FZh | 1000 N |
| Retention force | 10 N |
| Extraction force | 20 N |
| Actuating force | 10 N |
Electrical connection ratings
| Thermal rated current Ith | 4 A |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 4A 50V |
| DC-13 | 4A 24V |
| Solenoid operating voltage | |
| AC/DC | 24 V -15% … +10% |
| Short circuit protection according to IEC 60269-1 | |
| (Fuse) | 4A gG |
| Rated insulation voltage Ui | 50 V |
| Rated impulse withstand voltage Uimp | 1,5 kV |
| Switching voltage | |
| Min. at 10mA | 12 V |
| Switching current | |
| Min. at 24V | 1 mA |
| Power consumption | 8 W |
| Solenoid duty cycle | 100 % |
Reliability values according to EN ISO 13849-1
| Control of the guard locking | |
| Category | Depending on external control of guard locking |
| Performance Level | Depending on external control of guard locking |
| PFHD | Depending on external control of guard locking |
| Monitoring of guard locking and the safety guard position | |
| B10D | 3 x 106 |
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
| Overtravel A B C D E | 2 mm |
| Overtravel K L M N | 1,5 mm |
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
| Overtravel A B C D E | 7 mm |