Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage and LED function display
- 24 V AC/DC -15%, +10%
Guard locking type
| TZ2 | Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force. |
Switching element
| SK | For monitoring the door/actuator position |
| UK | For monitoring the guard locking (built-in solenoid) |
| 528H | Slow-action switching contact 1 NC + 1 NO |
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
| Housing material | Anodized die-cast alloy |
| Weight | |
| Net | 1,2 kg |
| Ambient temperature | -25 … 80 °C |
| Degree of protection | IP65 |
| Mechanical life | 1 x 106 |
| Contact material | Silver alloy, gold flashed |
| Switching principle | Slow-action switching contact |
| Installation orientation | Any |
| Number of door position positively driven contacts | 1 |
| Number of door position NO contacts | 1 |
| Number of guard lock monitoring positively driven contacts | 1 |
| Number of guard lock monitoring NO contacts | 1 |
| Connection | |
| 1 x | Plug connector SR6 |
| Approach speed | max.20 m/min |
| Actuation frequency | 1200 1/h |
| Guard locking principle | Open-circuit current principle |
| Locking force Fmax | 2000 N |
| Locking force FZh | 1500 N |
| Retention force | 10 N |
| Extraction force | 30 N |
| Actuating force | 35 N |
| Insertion depth | min.52 mm |
| Cover lid | Red |
Electrical connection ratings
| Thermal rated current Ith | 4 A 70°C => 2A’> |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 4A 230V 70°C => 2A’> |
| DC-13 | 4A 24V 70°C => 2A’> |
| Solenoid operating voltage | |
| AC/DC | 24 V -15% … +10% |
| Short circuit protection according to IEC 60269-1 | |
| (Fuse) | 4A gG 70°C => 2A gG’> |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 2,5 kV |
| Switching voltage | |
| Min. at 10mA | 12 V |
| Switching current | |
| Min. at 24V | 1 mA |
| Power consumption | 10 W |
| Solenoid duty cycle | 100 % |
| LED indicator | Operating voltage corresponds to the solenoid voltage |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position | |
| B10D | 3 x 106 |
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
| Overtravel | 16 mm |
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
| Overtravel | 4 mm |