3-stage functionEnabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram
Dimension drawingWiring diagramWiring diagramWiring diagram
Technical dataApprovals
Mechanical values and environment
| Material | PA, CR, TPE |
| Weight | |
| Net | 0,5 kg |
| Ambient temperature | -5 … 60 °C |
| Degree of protection | IP54 |
| Mechanical life | 1 x 106 |
| Switching principle | Snap-action contact element |
| Number of changeover contacts | 3 |
| Connection | Connection terminals, cable O 5…10mm |
Electrical connection ratings
| Rated conditional short-circuit current | 100 A |
| Utilization category according to EN 60947-5-1 | |
| DC-13 | 24V 1A |
| Short circuit protection according to IEC 60269-1 | 2A gG |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 1,5 kV |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Switching characteristics | 3-stage enabling switch |
Other
| Additional feature | |
| Version | Blind plug in hole for emergency stop |
| In compliance with | 60947-5-8 |
Reliability values according to EN ISO 13849-1
| Enabling switch | |
| B10D | 0,1 x 106 |