Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
| STATE | Status LED |
| DIA | Diagnostics LED |
Terminal assignment
| Designation | Function | Conductor coloring of connection cable |
|---|---|---|
| UB | Power supply, DC 24 V | BN |
| FO1A | Safety output, channel 1 | WH |
| 0V | Ground, DC 0 V | BU |
| FO1B | Safety output, channel 2 | BK |
| OD | Monitoring output | GY |
| Material | |
| Rubber support | NBR 80 ±5 Shore |
| Housing material | Plastic, PBT |
| Weight | |
| Net | 0,36 kg |
| Ambient temperature | |
| Cable static | -25 … 65 °C |
| Cable dynamic | -25 … 65 °C |
| Degree of protection | IP67 |
| Resilience to vibration | In acc. with EN IEC 60947-5-2 |
| Mounting method | Surface mounting on metal |
| Mounting distance | |
| Between 2 switches or 2 actuators | min.140 mm |
| Installation orientation | Any |
| Tightening torque | |
| Fixing screws | max.0,8 Nm |
| Ready delay | 0,5 s |
| Switching frequency | max.1 Hz |
| Connection | connection cable PUR, length 10m |
| Bending radius | |
| Dynamic | 10 x cable diameter |
| static | 5 x cable diameter |
Electrical connection ratings
| Operating voltage DC | |
| UB | 24 V DC 15% … 15% Regulated, residual ripple < 5%, PELV |
| Current consumption | |
| No load on outputs | max.35 mA |
| Fusing | |
| External (operating voltage) | 0,25 … 8 A |
| Rated insulation voltage Ui | 300 V |
| Rated impulse withstand voltage Uimp | max.1,5 kV |
| EMC protection requirements | In acc. with EN IEC 60947-5-3 |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Switch-on time | |
| Safety outputs | max.300 ms |
| Safety class | III |
| Risk time according to EN 60947-5-3 | max.260 ms |
| Monitoring output OD | |
| Type of output | p-switching, short circuit-proof |
| Switching current | max.50 mA |
| Output voltage | 0,8 x UB … UB V DC |
| Safety outputs FO1A / FO1B | |
| Test pulses | max.0,3 ms |
| Test-pulse interval | min.100 ms |
| Type of output | Semiconductor outputs, p-switching, short circuit-proof |
| Switching current | |
| per safety output | 1 … 150 mA |
| Output voltage | |
| HIGH U(FO1A) / U(FO1B) | UB-1,5V … UB V DC |
| LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
| Utilization category according to EN 60947-5-2 | |
| DC-13 | 24V 150mA |
| Rated conditional short-circuit current | 100 A |
| Off-state current Ir | max.0,25 mA |
| Discrepancy time | max.10 ms |
Work area
| Repeat accuracy R | ? 10 |
Other
| Additional feature | Rubber support included |
| For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position | |
| Category | 4 |
| Performance Level | PL e |
| PFHD | 4.1 x 10-9 |
| Mission time | 20 |
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
| Assured switch-off distance Sar | |
| In y direction | max.60 mm |
| In x/z direction | max.40 mm |
| Switching hysteresis | min.1 mm |
In combination with Actuator CES-A-BDN-06-104730Operating distance
| Switch-on distance | |
| Approach direction A or B (front side) | 19 mm |
| Approach direction C or D (broad side) | 15 mm |
| Assured operating distance Sao | |
| Approach direction A or B (front side) | min.14 mm |
| Approach direction C or D (broad side) | min.10 mm |
In combination with Actuator CES-A-BBN-C04-115271Operating distance
| Switch-on distance | |
| Approach direction C or D (broad side) | 11 mm |
| Approach direction A or B (front side) | 15 mm |
| Assured operating distance Sao | |
| Approach direction A or B (front side) | min.10 mm |
| Approach direction C or D (broad side) | min.6 mm |