AS-Interface inputs
| D0, D1 | Positively driven NC contact 1 |
| D2, D3 | Positively driven NC contact 2 |
Evaluation is performed via a safety monitor.
LED function display(internal with open cover)
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
Dimension drawing
| Housing material | Reinforced thermoplastic |
| Weight | |
| Net | 0,5 kg |
| Ambient temperature | -20 … 55 °C |
| Degree of protection | IP67 |
| Mechanical life | 2 x 106 |
| Contact material | Silver alloy, gold flashed |
| Switching principle | Slow-action switching contact |
| Installation orientation | Any |
| Number of door position positively driven contacts | |
| According to As-i Safety at Work | 2 D0, D1, D2, D3 |
| Connection | |
| 1 x | Plug connector M12 |
| Approach speed | |
| max. | 20 m/min |
| Actuation frequency | 6700 1/h |
| Retention force | 10 N |
| Extraction force | 25 N |
| Actuating force | 25 N |
| Insertion depth | 24,5 mm |
Electrical connection ratings
| ASi voltage | 30 V 22,5 … 31,6 V |
| ASi operating current | max.45 mA |
| ASi slave type | |
| According to ASI specification 2.1 | ID code: B |
| EA code: 7 | |
| ASi data in | |
| According to ASI safety at work | D0, D1, D2, D3 |
| ASi LED | |
| LED red | Fault |
| LED green | Power |
Reliability values according to EN ISO 13849-1
| B10D | 3 x 106 |
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
| Overtravel | 5 mm |