Euchner CET4-AP-CRA-CH-50X-SA-122413 (Order no. 122413)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 1 plug connector M12, 8-pin
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CDA-CH-50X-SG-114712 (Order no. 114712)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- With double ramp
- Approach direction A and C (default setting on delivery)
Euchner CET4-AR-CRA-AH-50F-SH-116285 (Order no. 116285)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M23 (RC18)
- Unicode
- Door monitoring output
- Teach-in input
- Escape release, 75 mm long
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-AH-50X-SG-111683 (Order no. 111683)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Indication of the door position by LED
- Teach-in input
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-AH-50X-SG-C2290-128193 (Order no. 128193)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Indication of the door position by LED
- Teach-in input
- Wire front release (bowden), 3 m
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-AH-50X-SH-110201 (Order no. 110201)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M23 (RC18)
- Unicode
- Door monitoring output
- Teach-in input
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-CH-50F-SG-114650 (Order no. 114650)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Escape release, 75 mm long
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-CH-50S-SG-113081 (Order no. 113081)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Feedback loop / start button
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-CH-50X-SG-111684 (Order no. 111684)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-CH-50X-SG-C2355-113609 (Order no. 113609)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-CH-50X-SH-110202 (Order no. 110202)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M23 (RC18)
- Multicode
- Door monitoring output
- Approach direction A (default setting on delivery)
Euchner CTP-I-AP-U-HA-ZZ-SA-136732 (Order no. 136732)
- Safety switch without guard locking, with integrated evaluation electronics
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Approach directions A, B and C (delivery state)
Euchner CTP-I-AP-U-HA-ZZE-SBB-159614 (Order no. 159614)
- Safety switch without guard locking, with integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET 200 pro)
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With two plug connectors M12
- Unicode
- Emergency stop
- Approach directions A, B and C (delivery state)
Euchner CTP-I1-AP-U-HA-AEC-SA-136595 (Order no. 136595)
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking suitable for process protection only
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- With escape release
- Door monitoring output
- Approach directions A, B and C (delivery state)
Euchner CTP-I2-AP-U-HA-AZC-SA-126258 (Order no. 126258)
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking suitable for process protection only
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)