Отображение 106–120 из 2827

Show sidebar
Показать 9 24 36
Euchner CES-AZ-AES-04B (Order no. 104780)
Закрыть

Euchner CES-AZ-UES-04B (Order no. 105141)

  • Four read heads can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Multicode
  • Plug-in connection terminals
  • Category 4/PL e according to EN ISO 13849-1
Euchner CES-FD-AP-M-01-USI-115534 (Order no. 115534)
Закрыть

Euchner CES-FD-AP-M-01-USI-115534 (Order no. 115534)

  • Evaluation of signals in the field
  • Connection of CES read heads
  • Connection to the ET200s and ET200pro
  • Familiar EUCHNER AP interface
  • Multicode
Euchner CES-FD-AP-M-01-USI-115534 (Order no. 115534)
Закрыть

Euchner CES-FD-AP-U-01-USI-119865 (Order no. 119865)

  • Evaluation of signals in the field
  • Connection of CES read heads
  • Connection to the ET200s and ET200pro
  • Familiar EUCHNER AP interface
  • Unicode
Euchner CES-I-AP-M-C04-SK-117325 (Order no. 117325)
Закрыть

Euchner CES-I-AP-M-C04-SK-117325 (Order no. 117325)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • With plug connector M8, 4-pin
  • Multicode
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 5 m, flying lead
  • Multicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-M-C04-U10-117329 (Order no. 117329)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 10 m, flying lead
  • Multicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-M-C04-U20-117330 (Order no. 117330)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead
  • Multicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-USB-117324 (Order no. 117324)
Закрыть

Euchner CES-I-AP-M-C04-USB-117324 (Order no. 117324)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 0.22 m, plug connector M12, 5-core
  • Multicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-USB-117324 (Order no. 117324)
Закрыть

Euchner CES-I-AP-M-C04-USI-117323 (Order no. 117323)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 0.1 m, plug connector M12, 5-core, pin 5 not used
  • Multicode
Euchner CES-I-AP-M-C14-U20-158631 (Order no. 158631)
Закрыть

Euchner CES-I-AP-M-C14-U20-158631 (Order no. 158631)

  • Safety switch with integrated evaluation electronics
  • Safety switch CES-C04 encapsulated in epoxy resin
  • Tested for material resistance in accordance with Ecolab specifications
  • Two safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 20 m, with cable end sleeves
  • Multicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-SK-117325 (Order no. 117325)
Закрыть

Euchner CES-I-AP-U-C04-SK-115324 (Order no. 115324)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • With plug connector M8, 4-pin
  • Unicode
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-U-C04-U05-116503 (Order no. 116503)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 5 m, flying lead
  • Unicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-U-C04-U10-116504 (Order no. 116504)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 10 m, flying lead
  • Unicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-U05-117328 (Order no. 117328)
Закрыть

Euchner CES-I-AP-U-C04-U20-116505 (Order no. 116505)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead
  • Unicode
  • Monitoring output OD
Euchner CES-I-AP-M-C04-USB-117324 (Order no. 117324)
Закрыть

Euchner CES-I-AP-U-C04-USB-116502 (Order no. 116502)

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 0.22 m, plug connector M12, 5-core
  • Unicode
  • Monitoring output OD