Dimension drawing
Wiring diagram
EKS FSA — Selection of safe operation mode with touch panels up to PL e
Dimension drawingWiring diagram
Technical dataApprovals
Mechanical values and environment
| Housing material | PA6-GF30 gray |
| Ambient temperature | 0 … 55 °C |
| Degree of protection | IP67 in installed state (only access side) |
| Mounting cut-out according to DIN 43700 | 33 x 68 mm |
| Installation orientation | On the front |
| USB interface | |
| Connection | USB full speed type B |
| Cable length | max.3 m USB |
Electrical connection ratings
| Current consumption | max.100 mA |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 24V 50mA |
| AC-12 | 24V 50mA |
| DC-12 | 24V 50mA |
| Utilization category according to EN 60947-5-2 | |
| DC-13 | 24V 50mA |
| Switching voltage | 24 … 30 V |
| Switching current | 1 … 10 … 50 mA With short circuit protection max. 100 times |
| Connection cross-section | 0,14 … 1,5 mm? |
| Discrepancy time | 200 ms Difference time between outputs (LB first) |
| LED indicator | |
| Green | Operational |
| Yellow | Key in operating distance |
Interface, bus
| USB interface | |
| Data protocol | 3964R via USB |
| Data rate | 9,6 … 28,8 kbit/s |
Other
| Additional feature | |
| 35 Resistance in switched-on state in Ohm | |
| max.1 Capacitive load per output in µF |